Power Station Driver Configuration version 01

Byte76543210
EEPROMReversible
Initial Polarity
0 = rail A in phase
with DCC1
reserved
Mode
0XXX DCC group
1000 PWM motor
1001 PWM lights
DRV_stenable driver
polarity, 1 = normal
reserved
reserved
coupled
shutdown for OC
auto-reverse attempted
auto-reversing driver
Coupled means this driver and at least one other driver are part of a group (must reverse together)
Note 1: Either rail A or rail B from the command station may be used as input with no change to this setting.
The phase of the incoming DCC is determined by the DCC state machine during the end of each preamble.
"In phase" means each bit begins with a low-to-high transition on the A rail.